Architectural Structural Columns Round, Smooth,
Tuscan Columns with Entasis
Round Tuscan Columns with entasis or "a taper",
are made of a cast composite of hi-tech resin, fiberglass and marble aggregate making them very strong, capable of bearing loads of up to 18,000 LBS each. The columns are guaranteed against rot,
insect damage and wear from the weather for 20 Years. The columns are also
highly resistant to physical abrasion and fire. With our optional
PostCore, installation is greatly
simplified and the structural qualities are greatly enhanced particularly when columns are used to support unbraced overhead loads such as an arbor. Tuscan Capital
and Base made of the same composite are included with each column.
Smooth 8" Diameter Tuscan Columns
8' HT without PostCore™ Including Capital & Base
$147
8' HT with PostCore™ Including Capital & Base
$232
Prices do not include shipping, please contact us at 800 686-3180 or email trellis@finehouse.net for a quote
Smooth 10" Diameter Tuscan Columns
8' HT without PostCore™ Including Capital & Base
$186
8' HT with PostCore™ Including Capital & Base...
$271
10' HT without PostCore™ Including Capital & Base
$220
10' HT withPostCore™ Including Capital & Base
$302
Prices do not include shipping, please contact us at 800 686-3180 or email trellis@finehouse.net for a quote
Smooth 12" Diameter Tuscan Columns
8' HT without PostCore™ Including Capital & Base
$255
8' HT with PostCore™ Including Capital & Base
$340
10' HT without PostCore™ Including Capital & Base
$304
10' HT withPostCore™ Including Capital & Base
$389
Prices do not include shipping, please contact us at 800 686-3180 or email trellis@finehouse.net for a quote
Learn More or Order
800-686-3180
All of our Architectural, Structural
Columns come with a 20 year guarantee
against rot, decay from the weather or damage from termites or other insects as well as defects in materials or workmanship.
Available
split in half for existing post application or to use as
a pilaster, call for a quotation
Additional notes on PostCore:
The
application and use of composite and fiberglass columns for
structural use, is coming under increasing scrutiny by building
officials nationwide. The ability of fiberglass or composite columns to resist lateral loads such as wind is negligable (see the ICC report ACCEPTANCE CRITERIA FOR FIBER-REINFORCED POLYMER (FRP)
COMPOSITE COLUMNS USED AS AXIAL LOAD-BEARING AND
NONLOAD-BEARING ARCHITECTURAL AND DECORATIVE COLUMNS). In particualar Sec 6.4 The answer to this dilema is the column
with PostCore by FineHouse. In
all cases, columns with PostCore can meet local code requirments when the PostCore™ is used as recommended by the local building official or structural engineer.